"The preferred industrial and commercial choice for 3-phase branch circuits, feeder systems, and heavy equipment assemblies. Engineered with a lightweight, interlocking aluminum armor jacket, this pre-protected 4-conductor plus ground assembly eliminates the material and labor costs of traditional conduit-and-wire piping. It allows electrical crews to pull high-capacity 3-phase circuits directly through walls, ceilings, and open cable trays in a fraction of the time.
When your project demands a reliable three-phase configuration or an independent neutral circuit, the 6/4 Aluminum Metal Clad (MC) Cable offers unmatched speed and protection. Built with lightweight, high-performance AA-8000 series aluminum alloy, this cable features four color-coded XHHW-2 insulated phase conductors and a dedicated bare grounding wire inside a flexible aluminum interlocked armor. It allows installation crews to complete complex multi-wire branch circuit runs in half the time of traditional pipe-and-wire setups.
Labor-Saving Armor: Overall aluminum interlocked armor functions as an integrated protective raceway, removing the labor and material expenses of bending and installing separate conduit systems.
Premium AA-8000 Conductor: Manufactured with compact-stranded 8000-series aluminum alloy for high electrical conductivity, low weight, and effortless flexibility during pull runs.
XHHW-2 Insulation: Individual phase conductors are insulated with cross-linked polyethylene (XLPE), providing superior resistance to heat, moisture, and electrical stress in wet or dry locations.
Maximum Versatility: Code-approved for an exceptionally broad range of installations including commercial branch circuits, HVAC units, equipment feeders, and environmental air-handling spaces (plenums).
Conductor Configuration: 4 Insulated Conductors + 1 Bare Ground Wire
Conductor Size: 6 AWG
Conductor Material: AA-8000 Series Compact Stranded Aluminum Alloy (per ASTM B800 & B801)
Conductor Colors: Black, White, Red & Blue
Ground Wire Size: 6 AWG (Bare Conductor)
Insulation: High-Heat & Moisture Resistant Cross-Linked Polyethylene (XLPE / Type XHHW-2). A binder tape is wrapped over the insulated conductors' assembly.
Armor: Overall aluminum interlocked armor.
Voltage Rating: 600 Volts.
Temperature Rating: -40C to 90C.
Amp Rating (@ 75C): 50 Amps.
Amp Rating (@ 90C): 55 Amps.
Outside Diameter (OD): 0.98 inches
Insulation Thickness: 0.045 inches
Net Weight: 328 lbs/mft (pounds per 1,000 feet)
Minimum Bending Radius: 6.86 inches
UL Listed: UL 1569 (Metal-Clad Cables) & UL 44 (Thermoset-Insulated Wires)
Cable Tray Use: Listed and approved for CT Use
Industry Standards: NEMA WC-70 / ICEA S-95-658 | ASTM B800 & B801
Flame Testing: Passes IEEE 1202 (70,000 BTU/HR Vertical Tray Flame Test)
NEC Air-Handling Compliance: Approved for environmental air spaces per NEC 300.22
NEC Special Occupancies: Approved for Places of Public Assembly (NEC 518.4), Theaters (NEC 520.5), and IT Equipment Rooms (NEC 645.5)
Commercial 3-Phase Power: Frequently utilized for 3-phase power distribution circuits, lighting, and control panels across industrial plants, retail centers, and commercial structures.
Diverse Environmental Routing: Fully approved for installation inside commercial cable trays, approved raceways, concealed or exposed locations, environmental air-handling spaces (plenums), and vertical structural risers.
Industrial Motor & Machinery Feeds: The industry standard for routing power to 3-phase motors, commercial kitchen ventilation, conveyor systems, and heavy production equipment.
Commercial HVAC Controls: Perfectly suited for feeding large-scale HVAC rooftop condensers, air handlers, and chiller systems requiring a dedicated neutral and grounding circuit.
Technical Note:Technical Note:All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyers responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes. Reference NEC Article 330 for specific Metal-Clad installation guidelines.
Ampacity:Ampacities are based on NEC Table 310.15 (B)(16) (or equivalent local reference tables) and show the allowable ampacities of current-carrying insulated conductors in a raceway, cable, or earth based on an ambient temperature of 30C (86F). Because most standard commercial electrical panels, breakers, and terminal lugs feature 75C termination points, circuits should be designed based on the conservative 50-Amp standard. The 55-Amp rating at 90C is typically utilized for ampacity adjustment and correction factors.
“The preferred industrial and commercial choice for 3-phase branch circuits, feeder systems, and heavy equipment assemblies. Engineered with a lightweight, interlocking aluminum armor jacket, this pre-protected 4-conductor plus ground assembly eliminates the material and labor costs of traditional conduit-and-wire piping. It allows electrical crews to pull high-capacity 3-phase circuits directly through walls, ceilings, and open cable trays in a fraction of the time.
When your project demands a reliable three-phase configuration or an independent neutral circuit, the 6/4 Aluminum Metal Clad (MC) Cable offers unmatched speed and protection. Built with lightweight, high-performance AA-8000 series aluminum alloy, this cable features four color-coded XHHW-2 insulated phase conductors and a dedicated bare grounding wire inside a flexible aluminum interlocked armor. It allows installation crews to complete complex multi-wire branch circuit runs in half the time of traditional pipe-and-wire setups.
Labor-Saving Armor: Overall aluminum interlocked armor functions as an integrated protective raceway, removing the labor and material expenses of bending and installing separate conduit systems.
Premium AA-8000 Conductor: Manufactured with compact-stranded 8000-series aluminum alloy for high electrical conductivity, low weight, and effortless flexibility during pull runs.
XHHW-2 Insulation: Individual phase conductors are insulated with cross-linked polyethylene (XLPE), providing superior resistance to heat, moisture, and electrical stress in wet or dry locations.
Maximum Versatility: Code-approved for an exceptionally broad range of installations including commercial branch circuits, HVAC units, equipment feeders, and environmental air-handling spaces (plenums).
Conductor Configuration: 4 Insulated Conductors + 1 Bare Ground Wire
Conductor Size: 6 AWG
Conductor Material: AA-8000 Series Compact Stranded Aluminum Alloy (per ASTM B800 & B801)
Conductor Colors: Black, White, Red & Blue
Ground Wire Size: 6 AWG (Bare Conductor)
Insulation: High-Heat & Moisture Resistant Cross-Linked Polyethylene (XLPE / Type XHHW-2). A binder tape is wrapped over the insulated conductors’ assembly.
Armor: Overall aluminum interlocked armor.
Voltage Rating: 600 Volts.
Temperature Rating: -40C to 90C.
Amp Rating (@ 75C): 50 Amps.
Amp Rating (@ 90C): 55 Amps.
Outside Diameter (OD): 0.98 inches
Insulation Thickness: 0.045 inches
Net Weight: 328 lbs/mft (pounds per 1,000 feet)
Minimum Bending Radius: 6.86 inches
UL Listed: UL 1569 (Metal-Clad Cables) & UL 44 (Thermoset-Insulated Wires)
Cable Tray Use: Listed and approved for CT Use
Industry Standards: NEMA WC-70 / ICEA S-95-658 | ASTM B800 & B801
Flame Testing: Passes IEEE 1202 (70,000 BTU/HR Vertical Tray Flame Test)
NEC Air-Handling Compliance: Approved for environmental air spaces per NEC 300.22
NEC Special Occupancies: Approved for Places of Public Assembly (NEC 518.4), Theaters (NEC 520.5), and IT Equipment Rooms (NEC 645.5)
Commercial 3-Phase Power: Frequently utilized for 3-phase power distribution circuits, lighting, and control panels across industrial plants, retail centers, and commercial structures.
Diverse Environmental Routing: Fully approved for installation inside commercial cable trays, approved raceways, concealed or exposed locations, environmental air-handling spaces (plenums), and vertical structural risers.
Industrial Motor & Machinery Feeds: The industry standard for routing power to 3-phase motors, commercial kitchen ventilation, conveyor systems, and heavy production equipment.
Commercial HVAC Controls: Perfectly suited for feeding large-scale HVAC rooftop condensers, air handlers, and chiller systems requiring a dedicated neutral and grounding circuit.
Technical Note:Technical Note:All values are nominal and subject to industry tolerances and manufacturer corrections. Specifications are subject to change without notice. It is the buyers responsibility to verify that all materials meet the specific requirements of the project and comply with local electrical codes. Reference NEC Article 330 for specific Metal-Clad installation guidelines.
Ampacity:Ampacities are based on NEC Table 310.15 (B)(16) (or equivalent local reference tables) and show the allowable ampacities of current-carrying insulated conductors in a raceway, cable, or earth based on an ambient temperature of 30C (86F). Because most standard commercial electrical panels, breakers, and terminal lugs feature 75C termination points, circuits should be designed based on the conservative 50-Amp standard. The 55-Amp rating at 90C is typically utilized for ampacity adjustment and correction factors.